Radiol. bras ; 40(1): 39-44, jan.-fev. 2007. tab
Article in Portuguese | LILACS | ID: lil-443804

ABSTRACT

OBJETIVO: O objetivo principal deste trabalho foi avaliar os serviços de radiodiagnóstico médico de dois hospitais públicos que fazem uso de equipamentos de raios X na cidade de Rio Branco, Acre. MATERIAIS E MÉTODOS: Foram realizadas entrevistas, medições e observações diretas, usando como referência a legislação brasileira em vigor, com especial ênfase à Portaria SVS/MS n° 453 de 1998, que estabelece as diretrizes básicas de proteção radiológica em radiodiagnóstico médico e odontológico. RESULTADOS: Os dados obtidos indicaram a ocorrência de elevado número de itens em desacordo com a legislação consultada em ambos os serviços radiológicos dos hospitais pesquisados, especialmente equipamentos funcionando de forma parcial e o descumprimento de alguns protocolos de segurança. CONCLUSÃO: As infrações técnicas ou operacionais foram, basicamente, em decorrência do desconhecimento sobre a legislação, a ausência de programa de manutenção preventiva dos equipamentos e da falta de investimentos em treinamentos e/ou cursos de atualização profissional. A melhoria dos serviços de radiodiagnóstico médico das instituições investigadas requer, portanto, uma série de modificações, que vão de simples às mais complexas.


OBJECTIVE: The main objective of the present study was to evaluate radiodiagnosis services in two public hospitals with x-ray equipment in the city of Rio Branco, Acre, Brazil. MATERIALS AND METHODS: Interviews, measurements and direct observation were performed, following the Brazilian legislation in force, especially the Order (Portaria) SVS/MS 453 of 1998 of the Ministry of Health establishing the basic guidelines for radiation exposure protection in medical and odontological x-ray facilities. RESULTS: The data indicated a high rate of non-compliance with the legislation in both radiological services, especially concerning poor equipment operation, and non-compliance with some safety protocols. CONCLUSION: Basically, technical and operational infractions have occurred as a result of a broad unfamiliarity with the legislation, the absence of a preventive equipment maintenance program, besides low investment in training and/or courses for professional updating. Therefore, a considerable number of simple and complex changes are demanded to improve the quality of the investigated radiodiagnosis services.


Subject(s)
Radiology Department, Hospital/standards , Diagnostic Services/standards , Health Services Research , Brazil , Quality Control , Radiology Department, Hospital/legislation & jurisprudence , Radiology Department, Hospital/organization & administration
SELECTION OF CITATIONS